Table 1 - Service Factors

The machines listed below are representative samples only. Select the group whose load characteristics closely match the machine being considered.

Types of Prime Mover

AC Motors: Normal Torque (NEMA A-B), Squirrel Cage, Synchronous, Split Phase
DC Motors: Shunt Wound Engines: Multiple Cylinder Internal Combustion

 

AC Motors: High Torque (NEMA C-D), High Slip, Repulsion, Induction, Single Phase, Slip Ring, Series Wound
DC Motors: Series Wound, Compound Wound
Engines: Single Cylinder Internal Combustion
Lineshafts, Clutches

Intermittent Service: 3-5 Hrs/Day or Seasonal Normal Service: 8-10 Hrs/Day Continuous Service: 16-24 Hrs/Day Intermittent Service: 3-5 Hrs/Day or Seasonal Normal Service: 8-10 Hrs/Day Continuous Service: 16-24 Hrs/Day
Type of DriveN Machine

Fans (up to 10 HP); Centrif ugal Pumps and Compressors; Conveyors (Light Duty)

1.0
1.1
1.2
1.1
1.2
1.3

Agitators: Liquid; Revolving and Vibrating Screens; Fans (over 10 HP); Generators; Machine Tools: Lathes, Mils, etc.; Line Shafts; Positive Displacement Rotary Pumps; Woodworking Equipment: Saws, Drils, Lathes, etc.

1.1
1.2
1.3
1.2
1.3
1.4

Brick Machinery; Agitators: Semi-Liquid; Presses, Punches, Shears; Pumps (Piston); Belt Conveyors: Ore, Coal, Sand, Aggregate; Compressors (Piston); Positive Displacement Blowers; Saw Mil Machinery; Textile Machinery

1.2
1.3
1.4
1.4
1.5